Wearable Gait Measure Associated With MS Disability Changes
KEY TAKEAWAYS
- Changes in gait stability measured using a wearable sensor were associated with changes in disability among people with multiple sclerosis.
- A nonlinear gait measure recorded by a sensor positioned at the sternum correlated with EDSS changes, whereas conventional walking speed did not.
- Findings support further investigation of wearable gait sensors as potential digital biomarkers for monitoring MS-related disability.
Changes in walking stability measured using wearable sensor technology were associated with changes in disability among people with multiple sclerosis (MS), even when conventional walking speed showed no corresponding association, according to findings presented at the 2026 Joint ACTRIMS-ECTRIMS Meeting (MSToronto2026). Findings from the preliminary study suggest that nonlinear gait measurements may capture aspects of neurologic impairment not reflected by traditional walking speed assessments.
Investigators conducted a secondary analysis of longitudinal clinical and instrumented gait data from 29 people with MS. The study evaluated the Lyapunov exponent (LyE), a nonlinear measure of gait divergence and instability derived from wearable inertial measurement units (IMUs). Researchers examined associations between changes in short-interval LyE (sLyE), walking speed, and Expanded Disability Status Scale (EDSS) scores. Eligible participants had reliable EDSS assessments obtained within 3 months before or 1 month after gait testing. The cohort had a mean age of 44 years and a mean EDSS score of 1.5.
Insights from the Gait Assessments
- Sternum sensor measurements: Changes in sLyE recorded using an IMU positioned at the sternum demonstrated a moderate inverse correlation with changes in EDSS after adjustment for age and baseline sLyE (partial Pearson r=−0.393; P=.042).
- Sensor placement: Changes in sLyE measured at the lower back were not significantly correlated with EDSS changes.
- Walking speed: Changes in mean walking speed measured over 5 minutes were not correlated with changes in EDSS, regardless of adjustment for age.
- Disability characteristics: Participants had EDSS scores ranging from 0 to 4, with observed EDSS changes ranging from −2.0 to 2.0.
The findings suggest that wearable sensors measuring gait stability may provide information about changes in MS-related disability beyond that obtained through conventional walking speed assessments. Investigators highlighted the potential for nonlinear gait measures to serve as responsive digital biomarkers and to support future remote monitoring, registry-based assessments, and telehealth applications.
However, the small sample size and preliminary observational findings warrant further validation before these measurements can be incorporated into routine clinical monitoring or used as established outcome measures.
Source
Panisset MG, Cofre Lizama E, Banakheiri T, Kalincik T, Galea M. Changes in non-linear digital biomarkers of gait instability (and not in walking speed) are strongly related to EDSS change. Abstract 2116. Presented at: 10th Joint ACTRIMS-ECTRIMS Meeting (MS Toronto 2026); October 21–23, 2026; Toronto, Canada.